Products

WOLONG WD400 Series General-Purpose VFD

Overview:The WD400 Series, developed by Wolong Electric, is a new-generation high-performance general-purpose vector AC drive designed for advanced industrial applications.Supporting both asynchronous and synchronous motors, the WD400 integrates multiple high...
Contact Us
WD400
  • Product introduction
  • Technical parameter
  • Product specification
  • WD400 产品彩页-英文版_page-0001.jpg
    WD400 产品彩页-英文版_page-0002.jpg
    WD400 产品彩页-英文版_page-0003.jpg
    WD400 产品彩页-英文版_page-0004.jpg
    WD400 产品彩页-英文版_page-0005.jpg
    WD400 产品彩页-英文版_page-0006.jpg
    WD400 产品彩页-英文版_page-0007.jpg
    WD400 产品彩页-英文版_page-0008.jpg
    WD400 产品彩页-英文版_page-0009.jpg
    WD400 产品彩页-英文版_page-0010.jpg

    WD400 产品彩页-英文版_page-0011.jpg


  • PERFORMANCE
    PARAMETER
    ItemsSpecification
    Supported motor typesAsynchronous induction motors (IM), Permanent magnet synchronous motors (PMSM)
    Control modeSensorless Vector Control (SVC); Field-Oriented Vector Control (FVC), V/F control
    ProtectionOvercurrent, Overvoltage, Buffer Resistor Overload Fault, Undervoltage, Inverter Overload, Motor Overload, Input Phase Loss, Output Phase Loss, Inverter Overheating, Buffer Resistor Engagement Fault, Current Zero Drift Detection Error, Ground Short Circuit Detection Fault, PWM Limiting Fault, Initial Position Fault, Tuning Failure, Signal Encoder Fault, Brake Resistor Direct Short, Brake Resistor Continuous On-Time Timeout, Back EMF Fault
    Asynchronous machine VFSupported  FunctionsEnergy-Saving Control, Overvoltage Suppression, Overcurrent Suppression, Voltage Dip Suppression, Oscillation Suppression, Torque Boost, Slip Compensation, Different VF Curve Selection, VF Separation, DC Braking, Overexcitation Rapid Deceleration, Droop Control
    Asynchronous machine FVCSupported  FunctionsElectronic Fusing, Overexcitation Rapid Deceleration, Master-Slave Control, MTPA Maximum Torque per Amp Control, Droop Control, Master-Slave Control, Overvoltage Suppression, Voltage Dip Suppression, Automatic Voltage Adjustment (AVR Generator Bus Voltage Control), DC Braking
    Encoder SupportABZ Encoder (Differential, Collector, Push-Pull), Encoder, Sine-Cosine Encoder
    Starting Torque 200%
    Torque Step ResponseTorque step response within 2ms
    Speed Stability Precision0.02%
    Speed Fluctuation0.05%
    Torque Control PrecisionTorque Control Precision ±2%
    Flux Weakening Factor5x Flux Weakening
    Asynchronous machine SVCSupported  FunctionsEnergy-Saving Control, Droop Control, Master-Slave Control, Load Observer, Overvoltage Suppression, Voltage Dip Suppression, Overexcitation Rapid Deceleration, Automatic Voltage Adjustment (AVR Generator Bus Voltage Control), Speed Tracking, DC Braking, etc.
    Speed Range1 : 500
    Starting Torque200%
    Torque Step ResponseTorque step response within 2ms
    Torque Control PrecisionTorque Control Precision ±3% above 5Hz
    Speed Accuracy10% within rated slip
    Flux Weakening
    Factor
    5x Flux Weakening
    Synchronous Machine FVCSupported  FunctionsElectronic Fusing, Overexcitation Rapid Deceleration, Master-Slave Control, MTPA Maximum Torque per Amp Control, Droop Control, Master-Slave Control, Overvoltage Suppression, Voltage Dip Suppression, Automatic Voltage Adjustment (AVR Generator Bus Voltage Control), DC Braking
    Encoder SupportABZ Encoder (Differential, Collector, Push-Pull), Encoder, Sine-Cosine Encoder
    Starting Torque200%
    Torque Step ResponseTorque step response within 2ms
    Speed Stability Precision0.02%
    Speed Fluctuation0.05%
    Torque Control PrecisionTorque Control Precision ±2%
    Synchronous Machine SVCSupported FunctionsSpeed Tracking, Electronic Fusing, Overexcitation Rapid Deceleration, Master-Slave Control, MTPA Maximum Torque per Amp Control, Droop Control, Master-Slave Control, Overvoltage Suppression, Voltage Dip Suppression, Automatic Voltage Adjustment (AVR Generator Bus Voltage Control), DC Braking.
    Speed Range1 : 200
    Starting Torque200%
    Torque Step ResponseTorque step response within 2ms
    Speed Stability Precision0.05%
    Torque Control PrecisionTorque Control Precision ±3% above 5Hz
    OTHER TECHNICAL
    PARAMETERS
    ItemsSpecification
    Supply VoltageSingle-Phase: 200V ~ 240V ±10%
    Three-Phase: 380V ~ 480V +15%/-10%
    Power Supply Frequency50/60Hz ±5%
    Power Range0.75kW~560kW
    Overload Capacity150% of rated current for 60 seconds
    Analog Input2 Channels: A11 (0–10V/0–20mA/4–20mA), Al2 (0–10V/0–20mA/4–20mA)
    Analog Output2 Channels: AO1 (0–10V/0–20mA/4–20mA), AO2 (0–10V/0–20mA/4–20mA)
    (1 AO output for 37kW and below)
    Digital Input7-Channel Programmable Digital Input (with a maximum input frequency of 1KHz and an internal impedance of 4.4KΩ)
    (5 digital inputs for 37kW and below)
    Digital Output1-Channel Programmable Open-Collector Logic Output (with a maximum current of 1.2mA when powered by internal supply and a maximum current of 200mA when powered by external supply)
    1-Channel High-Speed Pulse Output (with a maximum frequency of 100kHz)
    Relay Output2-Channel Programmable Relay Output: TAI/NO1 Normally Open Contact; TB1/NC1 Normally Closed Contact; TC1/CM1 Common Terminal TB2/NO2 Normally Open Contact; TC2/CM2 Common Terminal
    (1 relay output for 37kW and below)
    Communication InterfacesModbus RTU Communication: A+/B-/485G
    Expansion Interfaces2 Expansion Interfaces: SLOT,SLOT2
    Options: I/O expansion modules, speed feedback encoder modules,
     communication modules, etc
    Fieldbus Adapter ModuleProfibus-DP, Profinet, EtherNET, EtherCAT, CANopen
    I/O Expansion Module4 Digital Inputs (including 1 high-speed input);
    1 Digital Output; 1 Analog output; 1 Relay Output
    1 Temperature Input (PT100/PT1000)
    Brake UnitStandard built-in for 0.75–22kW
    Optional built-in for 30–160kW
    Optional external for above 160kW
    DC ReactorStandard Built-in for 30KW and above
    Installation MethodsRail Mounting; Wall Mounting; Flange Mounting; Floor Standing
    Cooling MethodForced Air Cooling
    Protection LevelIP20
    Operating Temperature -10°C ~ +50°C (derating is required for temperatures above 40°C,
    and derate by 1.5% for every 1°C higher than 40°C)
    Storage Temperature -20°C ~ + 60°C
    ComplianceIEC61800-5-1; GB12668
    Harmonic SuppressionMeets IEC61800-2 requirements
    G: Heavy Load            P: Standard LoadMotorPower Supply (Input)Frequency Converter (Output)ModelOverall DimensionsInstallation DimensionsAperturePackage sizegross weight
    Rated powerLine Current Max Continuous Output Current Max Instantaneous Frequency Load
    W1 D1H1W2 H2Length WidthHeight
    kWHPAAA
    mmmmmmmmmmmmmmmmmmkg
    G0.7513.534.5WD400-T3-R75G-B80155200651903-Ø52362061371.6
    G1.52546WD400-T3-1R5G-B80155200651903-Ø52362061371.6
    G2.235.869WD400-T3-2R2G-B80155200651903-Ø52362061371.6
    G45111015WD400-T3-004G-B100155242842324-Ø52912161672.2
    G5.57.5151319.5WD400-T3-5R5G-B100155242842324-Ø52912161672.2
    G7.510201725.5WD400-T3-7R5G-B116175320983084-Ø63842522044.2
    G1115262537.5WD400-T3-011G-B116175320983084-Ø63842522044.3
    G1520353248WD400-T3-015G-B1422253831203724-Ø64493122397
    G18.525393857WD400-T3-018G-B1422253831203724-Ø64493122397.4
    G2230464567.5WD400-T3-022G-B1422253831203724-Ø64493122397.4
    G3040626090WD400-T3-030G1702254301504164-Ø6527322279/
    G37507675112.5WD400-T3-037G1702254301504164-Ø6527322279/
    G45609090135WD400-T3-045G2403105601765454-Ø7620335415/
    G5575105110165WD400-T3-055G2403105601765454-Ø7620335415/
    G75100140150225WD400-T3-075G2403105601765454-Ø7620335415/
    G90125160180270WD400-T3-090G2703506381956154-Ø10670365450/
    G110150210210315WD400-T3-110G2703506381956154-Ø10670365450/
    G132200240250375WD400-T3-132G3503907352207154-Ø10790465510/
    G160250290310465WD400-T3-160G3503907352207154-Ø10790465510/
    G185248330340510WD400-T3-185G3604859422008904-Ø121073483633/
    G200275370380570WD400-T3-200G3604859422008904-Ø121073483633/
    G220300410415622.5WD400-T3-220G3604859422008904-Ø121073483633/
    G250340460470705WD400-T3-250G370545112720010754-Ø201250493713/
    G280380500510765WD400-T3-280G370545112720010754-Ø201250493713/
    G315430580600900WD400-T3-315G400545121224011474-Ø201335523693/
    G3554856206701005WD400-T3-355G400545121224011474-Ø201335523693/
    G4005456707501125WD400-T3-400G400545121224011474-Ø201335523693/
    G4506007808001200WD400-T3-450G460545140030013404-Ø201523583748/
    G5006758358601290WD400-T3-500G460545140030013404-Ø201523583748/
    G5607509209901485WD400-T3-560G460545140030013404-Ø201523583748/


  • WD400参数表_OTHER TECHNICAL PARAMETERSOTHER.jpg
    WD400参数表_PERFORMANCE PARAMETER.jpg
    WD400产品数据_尺寸重量.jpg
    WD400产品数据_电气数据.jpg


Applications

Contact Us

Be the first to know about our new product launches, latest blog posts and more.
Founded in 1984, Wolong is a global leader in motor and drive technology, providing safe, efficient,...

Any question or request?

Click below, we’ll be happy to assist. Contact Us
Copyright © 2026 Wolong VFD Electric Group. All rights reserved.